PYROGENICITY in EBI

/ | Leave a Comment

  PYROGENICITY is the ability of a chemical agent or other substance to produce a febrile response.Pyrogenic responses may be material-mediated, endotoxin-mediated, or mediated by other substances.In accordance with the ISO 10993-11 we commonly conduct two test types:LAL (Limus Amebocyte Lisate) test to detected endotoxin-specific factors,Material-mediated pyrogenicity test (Rabbit Pyrogen Test) which has a wide […]

Read more

Medical devices, that come to contact with blood

/ | Leave a Comment

An important part of the products we handle are medical devices, that come to contact with blood (blood paths, circulating blood). For such devices, a dedicated group of tests needs to be performed, described in 10993-4, called hemocompatibility tests. This part of the biocompatibility evaluation process consists of many different parts, among which the most […]

Read more

Genotoxicity studies, carried out according to ISO 10993-3 and 10993-33

/ | Leave a Comment

One of the most interesting studies carried out in our laboratory are genotoxicity studies, carried out according to ISO 10993-3 and 10993-33. We conduct genotoxicity with both prokaryotic (bacterial strains – AMES method) and eukaryotic test systems (mammalian cell lines – Mouse Lymphoma Assay). Genotoxicity testing applies to various kinds of medical devices, ranging from […]

Read more

EBI is ISO 17025 accredited!

/ | Leave a Comment

By the decision of the Polish Accreditation Center (PCA), we obtained ISO 17025 accreditation! From this moment, European Biomedical Institute is ISO 17025 accredited with the accreditation number AB 1763. The main purpose of implementing the ISO 17025 system is to improve the quality of tests and measurements performed. The requirements of the ISO 17025 […]

Read more

ISO 10993-23:2021 Biological evaluation of medical devices – Part 23: Tests for irritation.

| Leave a Comment

ISO 10993-23:2021 Biological evaluation of medical devices – Part 23: Tests for irritation. The long-awaited ISO 10993-23 Biological evaluation of medical devices – Part 23: Tests for irritation has been finally published!   Irritation tests of medical devices were taken out from ISO 10993-10, and now are fully described in dedicated ISO 10993-23 – many […]

Read more

New Walletmor payment implant certified by ISO tests in Konmex BioLabs!

| Leave a Comment

We are heappy to annouce that the Walletmor payment implant has successfully passed cytotoxic testing. Check more!

Read more